Pupillary Distance Tool: Measure Your PD Online
Get your distance PD, mono PD for each eye and an honest uncertainty range from one straight-on photo or your camera, using your iris as the ruler instead of a card.
Free no signup478 landmarksOn-device no upload~3 s to result
Front-facing · neutral expression · even light
Try it with your own photo
Runs 100% in your browser · the free scan never uploads your photo
Method
How it works and the exact formula
Pupillary distance (PD) is the distance between the centers of your pupils in millimetres. Glasses are made so the optical center of each lens sits in front of your pupil; when it does not, a prescription lens acts slightly like a prism, which matters more the stronger the prescription. Online glasses shops ask for your PD because it is often not written on the prescription itself.
The difficulty with measuring from a photo is scale: a photo shows pixels, not millimetres. Many apps ask you to hold a bank card against your forehead as a ruler, but the card sits slightly in front of your eyes and must be held flat and straight. This tool uses a ruler you already carry: your iris. The visible iris diameter, which eye-care professionals measure as the horizontal white-to-white corneal diameter, varies surprisingly little between adults. It averages about 11.7 mm, with most people between roughly 11.0 and 12.4 mm, and it sits in the same plane as the pupils you are measuring.
MediaPipe Face Landmarker returns a center point and four ring points for each iris: 468 with 469–472, and 473 with 474–477. We level the face on the line between the iris centers, then estimate each iris diameter as twice the mean distance from the center to its four ring points. The scale is 11.7 mm divided by the average of the two diameters in pixels. Your distance PD is the pixel distance between the two iris centers multiplied by that scale. Mono PD, the per-eye value opticians use for progressive and high-prescription lenses, is the horizontal distance from each pupil to the nasal midline at the bridge of the nose (landmark 168), multiplied by the same scale.
The honest limit is the iris assumption itself. If your iris measures 11.0 mm rather than 11.7 mm, every result is about 6% too large; if it measures 12.4 mm, about 6% too small. So next to your PD the tool shows a range from PD × 11.0 ÷ 11.7 to PD × 12.4 ÷ 11.7. For a 62 mm reading that is about 58.3 to 65.7 mm, roughly ±3.7 mm. Near PD, used for reading glasses, is about 3 mm less than distance PD because the eyes turn inward to focus on close objects.
For the best reading, look straight into the camera lens rather than at the screen, take off your glasses (lenses magnify or shrink the iris), keep your head level and make sure your face fills at least a quarter of the photo width so each iris spans enough pixels. Even, frontal light helps the ring points lock onto the edge of the iris rather than the shadow of the eyelid. Average two or three readings if they differ.
Formulas
- Iris diameter
- d = 2 × mean(|L468 − L469…472|), likewise L473 with L474…477
- Scale
- mm per px = 11.7 ÷ ((d_left + d_right) ÷ 2)
- Distance PD
- PD = |L468 − L473| × scale
- Mono PD
- mono = |x_iris − x_168| × scale, for each eye after levelling
- Uncertainty range
- PD × 11.0 ÷ 11.7 to PD × 12.4 ÷ 11.7
- Near PD (estimate)
- near ≈ PD − 3 mm
MediaPipe landmarks used
| Anatomical point | Index | Role |
|---|---|---|
| Iris centers | 468 / 473 | Pupil positions; their distance is the PD in pixels. Also level the face. |
| Left iris ring | 469–472 | Four points on the iris edge; twice their mean radius is the iris diameter. |
| Right iris ring | 474–477 | The same for the other iris; both diameters are averaged for the scale. |
| Glabella (nasal midline) | 168 | Midline reference for each eye's mono PD. |
Do it by hand
How to measure it yourself, and the photo's limits
How to measure your pupillary distance with a ruler
- 1
Stand about 20 cm from a mirror and hold a millimetre ruler flat and level against your brow, just above your eyes.
- 2
Close your right eye and line up the ruler's zero with the center of your left pupil.
- 3
Without moving the ruler or your head, close your left eye, open your right, look straight ahead and read the mark at the center of your right pupil; that number is your distance PD.
- 4
For mono PD, ask someone at your eye level to measure from the center of your nose bridge to each pupil while you look at a distant point over their shoulder.
- 5
Repeat the whole measurement three times and average it, then subtract about 3 mm if you need a near PD for reading glasses.
What a photo can and can't tell you
- The scanner converts pixels to millimetres by assuming an 11.7 mm iris, so a smaller or larger iris scales every result, which is why it shows a range.
- Glasses worn in the photo magnify or shrink the iris and throw off the scale, so remove them before measuring.
- Looking at the screen instead of the camera lens turns both eyes slightly inward and shortens the measured PD.
- In the mirror method, any head movement between closing one eye and the other shifts the ruler against your pupils, so trust an average rather than one reading.
- When the face is small in the frame, each iris spans only a few pixels and rounding in its diameter feeds straight into the scale.
Benchmarks
Reference values for pupillary distance and iris size
| Measurement | Group | Typical range | Mean | Used for |
|---|---|---|---|---|
| Distance PD | Adults | 54 – 74 mm | ≈ 63 mm | Single-vision distance glasses |
| Distance PD | Women | within the adult range | ≈ 61.7 mm | Single-vision distance glasses |
| Distance PD | Men | within the adult range | ≈ 64.0 mm | Single-vision distance glasses |
| Mono PD | Each eye | about half of PD | ≈ 31.5 mm | Progressive and high-prescription lenses |
| Near PD | Adults | distance PD minus about 3 mm | ≈ 60 mm | Reading and close-work glasses |
| Iris diameter | Adults | 11.0 – 12.4 mm | ≈ 11.7 mm | The ruler this tool assumes |
| Tool range | A 62 mm reading | 58.3 – 65.7 mm | 62 mm | Uncertainty from individual iris size |
PD values come from Dodgson's review of published anthropometric surveys and iris size from corneal white-to-white measurements (Rüfer et al.). They are reference ranges from the literature, not data collected from our users: the tool never uploads or stores your photo. Left and right mono PD often differ by a millimetre or so.
Styling
Styling and virtual try-on by result
PD is the bridge between your face and your frames. Use it to shortlist frames, sanity-check an online order and decide when a professional measurement is worth it.
PD under 58 mm
Compare your PD with the frame PD, which is lens width plus bridge width (both printed on the inside of the temple arm). The closer they are, the less the lab has to shift the lenses off center, so smaller frames usually fit a small PD best.
Find frames for your facePD 58–68 mm
Most standard adult frames fit this range, so choose by face shape and eye spacing first. Keep the frame's widest point close to your cheekbone width for balance.
Check your eye spacingPD over 68 mm
Look for a larger lens width or wider bridge so the frame PD is not far below yours; very narrow frames push the optical centers toward the outer edge of the lens.
See wider frame stylesProgressive or strong prescription
Treat this reading as a check only. Ask an optician to measure your mono PD and fitting height with the actual frame on, because those lenses depend on precise placement.
Read about measurement normsRange wider than you'd like
Retake the photo with your face filling more of the frame, glasses off and eyes on the lens, then average two or three readings. The iris-size range itself does not shrink with more photos.
Check how level your eyes arePupillary Distance Tool: frequently asked questions
What is a normal pupillary distance?
For adults, distance PD typically falls between about 54 and 74 mm, with an average near 63 mm. Women average about 61.7 mm and men about 64.0 mm in published surveys. A reading outside that range is possible but worth re-measuring.
How accurate is measuring PD from a photo?
The landmark positions are consistent on a sharp, frontal photo, so the main uncertainty is the assumed iris size. Because adult irises range from about 11.0 to 12.4 mm, the tool shows a range of roughly ±3.7 mm around a 62 mm reading. An optician's pupillometer or ruler measurement is more precise.
Why use the iris instead of a credit card?
A card has to be held flat against the forehead, which sits slightly in front of the eyes, and it is easy to tilt. The iris is already in the plane of the pupils and needs no extra object. The trade-off is that iris size varies between people, which is why the tool reports a range.
What is the difference between single PD and dual (mono) PD?
Single PD is the total distance between the pupils. Dual or mono PD splits it into two numbers, one from each pupil to the center of the nose bridge, written like 31.5/32. Faces are rarely perfectly symmetric, so the two halves often differ slightly; progressive lenses use the mono values.
What is near PD and do I need it?
Near PD is your pupillary distance when you focus on something close, such as a book. Your eyes converge, so it is about 3 mm less than distance PD. Reading-only glasses use near PD; distance and everyday glasses use distance PD.
Can I use this PD to order glasses online?
For simple single-vision glasses it is a useful check against what you were given before. For progressive, bifocal, multifocal or high prescriptions it is not a substitute for an optician's measurement, so follow your eye-care professional's advice for those.
Does it work with glasses on or for children?
Take glasses off: the lenses magnify or shrink the iris and break the scale. The reference values and ranges on this page are for adults, so ask an optician to measure children for glasses.
Is my photo uploaded to measure PD?
No. The face mesh and every calculation run in your browser, and the photo or camera feed never leaves your device.
References
- Dodgson NA (2004). Variation and extrema of human interpupillary distance. Proc. SPIE 5291, Stereoscopic Displays and Virtual Reality Systems XI, 36–46.
- Rüfer F, Schröder A, Erb C (2005). White-to-white corneal diameter: normal values in healthy humans obtained with the Orbscan II topography system. Cornea 24(3):259–261.
- Grishchenko I, Ablavatski A, Kartynnik Y, Raveendran K, Grundmann M (2020). Attention Mesh: High-fidelity Face Mesh Prediction in Real-time. CVPR Workshop on Computer Vision for AR/VR.
- Kartynnik Y, Ablavatski A, Grishchenko I, Grundmann M (2019). Real-time Facial Surface Geometry from Monocular Video on Mobile GPUs. CVPR Workshop on Computer Vision for AR/VR.
Keep exploring
Related free tools and guides
Free tool
Glasses Finder
Get frame shapes matched to your face shape, plus bridge advice from your measured eye spacing, then try them on virtually.
Free tool
Eye Shape Detector
Measure how open, how tilted and how far apart your eyes are, get your eye shape in plain words, and see the liner, lash and frame moves that suit it.
Free tool
Face Symmetry Test
Find out how symmetric your face is with a 0–100 score from 12 mirrored landmark pairs, corrected for head tilt.
Free tool
Canthal Tilt Calculator
Measure the angle between your inner and outer eye corners in degrees, for each eye, after levelling your head.
Guide
Facial Measurement Norms: Average fWHR, Canthal Tilt, Symmetry and Profile Angles
Guide
Complete 12-Season Personal Color Palette Guide: Spring, Summer, Autumn, Winter
Guide
FaceIQ Labs Alternative: Free Front and Side Facial Ratio Analysis
Found a haircut, neckline or pair of glasses you like? Rate it on your own photo in the Try-On Studio